Industrial IoT Monitoring System
Wireless sensors, local gateway and web platform for monitoring industrial equipment.
- Motors, conveyor systems, sorters, critical zones
- Vibration, temperature, current, RPM, digital events
- Local gateway and online dashboard
- Configurable for battery, external power or mixed deployments

AnySensor at a glance
From equipment to platform
Sensor nodes
vibration, temperature, current, RPM/speed, digital events
Wireless link
industrial telemetry to gateway, RF profile configured for the application
AnySensor Gateway
local receiver, configurable buffering, backhaul to platform
Backhaul
Ethernet / Wi-Fi / cellular, adapted to existing infrastructure
AnySensor Platform
dashboards, history, thresholds, alerts, reports and indicators

The final configuration is set according to the application, infrastructure and RF environment.
AnySensor Node + Gateway

AnySensor Node
Fixed node installed on or near equipment for industrial signal collection.
| Parametru | Specification |
|---|---|
| Role | fixed equipment monitoring |
| Communication | wireless to gateway |
| Power | battery, external power or mixed configuration |
| Sensors | configured for the client application |
| Sampling | periodic, event-based or burst |
| Mounting | magnetic, screw, bracket or custom solution |
| Enclosure | industrial, adapted to the operating environment |
| Device identity | node associated in gateway and platform |

AnySensor Gateway
Local gateway for collecting node data and transmitting it to the platform.
| Parametru | Specification |
|---|---|
| Role | data collection from AnySensor nodes |
| Radio | industrial radio for telemetry |
| Backhaul | Ethernet, Wi-Fi or cellular |
| Power | industrial supply, cabinet or mains |
| Node capacity | sized by transmission interval, payload and RF environment |
| Local buffering | configurable spool for platform transmission |
| Installation | electrical cabinet, technical area or near the system |
Sensor and signal options

| Signal | Tracks | Typical mounting |
|---|---|---|
| Vibration | imbalance, bearing wear, shocks, abnormal vibration | motor housing, bearing area, roller assembly |
| Temperature | overheating, friction, abnormal load | motor, bearing, cabinet, contact surface |
| Current | increased load, blockage, abnormal consumption | motor feed, electrical panel, CT/Hall sensor |
| RPM / speed | speed variation, slip, stops | shaft, roller, drive, encoder point |
| Digital events | running/stopped, alarm, sensor state, contact | panel, relay, PLC signal, digital input |
| Runtime / status | runtime, cycles, starts/stops | derived from digital, current or PLC signal |
| Audio / noise | abnormal mechanical noise, acoustic changes | near equipment, protected mount |
| Distance / proximity | object presence, product pass, relative position | conveyor system area, guide, equipment input/output |
| Pressure / pneumatic | pressure loss, incorrect pneumatic mode | air line, distributor, pneumatic cabinet |
| Industrial analog input | existing 0-10V / 4-20mA signals | cabinet, existing sensor, signal interface |
| Voltage / supply | voltage drop, brownout, unstable supply | equipment supply, cabinet, local source |
| Humidity / environment | ambient conditions relevant to equipment | cabinet, technical area, near equipment |
Battery autonomy simulator
indicative profile for battery and slow trends
Main settings
Advanced settings
Currents, durations and radio parameters for technical calculation.
Radio
Sampling
Sensor tuning
The simulator helps choose the right profile for battery or external power.
Power and autonomy interpretation
Low-duty battery
Infrequent sampling, rare transmissions and short sensor activity. Suitable for high autonomy.
Standard monitoring
Multiple signals and regular transmission for equipment where operational visibility matters.
Intensive sampling
Frequent captures, bursts or longer sensor activity. External power is recommended.
Communication and gateway sizing
Communication
link for industrial node-gateway telemetry
adapted to site infrastructure
existing signal intake where available
structure used for history, alerts and reports
Gateway sizing
for critical assets
typical monitoring profile
good profile for battery nodes
depends on event rate
Platform and capabilities

Commercial structure
AnySensor Start
- Includes
- selected fixed nodes, local gateway
- Software
- initial dashboard, signal history
- Services
- equipment mapping, sampling profile, technical report
- Recommended for
- defining the configuration for expansion
AnySensor Fixed Monitoring
- Includes
- fixed sensor nodes, gateways
- Software
- dashboards, thresholds, reports
- Services
- signal configuration and maintenance insights
- Recommended for
- permanent monitoring on critical equipment
AnySensor Platform
- Includes
- hardware sized separately
- Software
- dashboards, data history, rules, reports, user access
- Services
- operational configuration and reporting
- Recommended for
- software visibility and operational reporting
AnySensor Integration
- Includes
- sensor/gateway selection by site
- Software
- API/export/specific configurations
- Services
- equipment mapping, installation support, dashboards/reports
- Recommended for
- implementation and customization
What we define before quoting
Checklist for commercial and technical client discussions.
motors, conveyor systems, sorters, critical zones
approximate number and location on equipment
vibration, temperature, current, RPM, digital, analog
battery, external or mixed
Ethernet, Wi-Fi, cellular or isolated
low-duty, standard, burst or event-based
rules, notifications, prioritisation
equipment, zones, signals, reports
history, export, derived indicators
environment, access, safety, enclosure